What is CVE-2024-49775?
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence (All versions < V2501.0001), Opcenter Quality (All versions < V2512), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.
The record classifies CVE-2024-49775 under weakness class CWE-122. Its CVSS v3 base vector states that the flaw is reachable remotely over the network, needs no prior authentication, needs no user interaction, and has high impact on confidentiality, integrity, availability. 12 affected-product entries are recorded, across 1 vendor, listed below. The identifier was first published 668 days ago.
Severity and exploitation probability
- CVSS v3.1 base score
- 9.8 — CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS v4.0 base score
- 9.3
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N - EPSS (FIRST)
- 1.4% probability of exploitation in the next 30 days, higher than 73.5% of all scored CVEs
- CISA KEV
- Not listed in the CISA Known Exploited Vulnerabilities catalog
- Threadlinqs priority
- 9.8/10 — a Threadlinqs composite of the CVSS base score, the EPSS percentile and public exploit availability
- Published
- 2024-12-16, last modified 2026-01-13
Is CVE-2024-49775 being exploited?
Weaponised exploit code for CVE-2024-49775 is publicly available. 1 public proof-of-concept repository is tracked for this identifier. It currently carries a trending score of 31 in the Threadlinqs vulnerability feed.
- trickest/cve (trickest)
Affected products and versions
- Siemens: Opcenter Execution Foundation, Opcenter Intelligence, Opcenter Quality, Opcenter RDnL, SIMATIC PCS neo V4.0, SIMATIC PCS neo V4.1, SIMATIC PCS neo V5.0, SINEC NMS, Totally Integrated Automation Portal (TIA Portal) V16, Totally Integrated Automation Portal (TIA Portal) V17, Totally Integrated Automation Portal (TIA Portal) V18, Totally Integrated Automation Portal (TIA Portal) V19
How to fix CVE-2024-49775
No vendor patch reference has been recorded for CVE-2024-49775 in the tracked sources. Follow the references below for a fix, and treat the products listed above as exposed until the vendor states otherwise.
Threat activity tracking CVE-2024-49775
1 tracked threat in the Threadlinqs corpus references CVE-2024-49775, either in the campaign’s CVE list or as an indicator on the campaign record.
Sources
Enriched from CVE.org, FIRST EPSS, GitHub Security Advisories, public proof-of-concept repositories. Last verified by Threadlinqs on .