# CVE-2026-16675 — Rockwell Automation FactoryTalk® Activation Manager

> As of 2026-11-15, CVE-2026-16675 is a High-severity (band derived from the CVSS v4.0 score, not stated by the CNA) vulnerability in Rockwell Automation FactoryTalk® Activation Manager, CVSS v4.0 8.5, EPSS 0.1% (3.1th percentile). Threadlinqs Intelligence links 1 tracked threat campaign to CVE-2026-16675, most recently “Rockwell Automation FactoryTalk Activation Manager Privilege Escalation via Installer Repair Console Hijack (CVE-2026-16675, KLCERT-25-153)”.

**Last updated:** 2026-11-15

## What is CVE-2026-16675?

A privilege escalation security issue exists within FactoryTalk® Activation Manager. The security issue stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows credentials could hijack these console windows to obtain a SYSTEM-level command prompt, allowing full access to all files, processes, and system resources.

The record classifies CVE-2026-16675 under weakness class [CWE-307](https://intel.threadlinqs.com/cwe/CWE-307). 1 affected-product entry is recorded, across 1 vendor, listed below. The identifier was first published 76 days ago.

## Severity and exploitation probability

- **CVSS v4.0 base score:** 8.5 — High (derived from score) (`CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N`)
- **EPSS (FIRST):** 0.1% probability of exploitation in the next 30 days, higher than 3.1% of all scored CVEs
- **CISA KEV:** Not listed in the CISA Known Exploited Vulnerabilities catalog
- **Threadlinqs priority:** 4.4/10 — a Threadlinqs composite of the CVSS base score, the EPSS percentile and public exploit availability
- **Published:** 2026-09-01

## Is CVE-2026-16675 being exploited?

It currently carries a trending score of 17 in the Threadlinqs vulnerability feed.

## Affected products and versions

- [Rockwell Automation](https://intel.threadlinqs.com/vendors/rockwell-automation): FactoryTalk® Activation Manager

## How to fix CVE-2026-16675

No vendor patch reference has been recorded for CVE-2026-16675 in the tracked sources. Follow the references below for a fix, and treat the products listed above as exposed until the vendor states otherwise.

## Threat activity tracking CVE-2026-16675

1 tracked threat in the Threadlinqs corpus references CVE-2026-16675, either in the campaign’s CVE list or as an indicator on the campaign record.

- [Rockwell Automation FactoryTalk Activation Manager Privilege Escalation via Installer Repair Console Hijack (CVE-2026-16675, KLCERT-25-153)](https://intel.threadlinqs.com/threat/TL-2026-6109) — HIGH · 2026-11-15

## Sources

Enriched from CVE.org, FIRST EPSS, GitHub Security Advisories.

**Other references**

- [rockwellautomation.com](https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1799.html)