Threat reportVulnerabilityTL-2026-6880
CVE-2026-97180: OS Command Injection in ASSA ABLOY Seawing SC-1000 WebConfig (versions before 1.5.14)
CERT Polska and the vendor (SEAWING-SA-2026-01) disclose an OS command injection (CWE-78) in the ASSA ABLOY Seawing SC-1000 WebConfig interface: unsanitized input in the `server` parameter of an HTTP request lets a privileged attacker run arbitrary commands as root. All versions before 1.5.14 are affected; 1.5.14 fixes the issue. First disclosed .
Key facts
| Identifiers | TL-2026-6880, CVE-2026-97180 |
|---|---|
| Also known as | SEAWING-SA-2026-01 |
| Severity | CRITICAL |
| CVSS | 9.4 (CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H) |
| First disclosed | |
| Affected products | ASSA ABLOY Seawing SC-1000 WebConfig |
| Weaknesses (CWE) | CWE-78 |
| MITRE ATT&CK techniques | T1059 Command and Scripting Interpreter, T1059.004 Command and Scripting Interpreter: Unix Shell, T1078 Valid Accounts, T1190 Exploit Public-Facing Application |
| Motivation | UNKNOWN |
| Target sectors | physical-security, critical-infrastructure, commercial-facilities |
| Target regions | Europe |
| Detection rules | 9 (1 shown free) |
| Sources | 9 cited sources |
Detection coverage
As of 2026-11-25, Threadlinqs Intelligence publishes 9 detection rule(s) for TL-2026-6880 across Splunk SPL, Microsoft KQL and Sigma, covering 11 indicator(s) of compromise. The whole corpus is readable without an account. Every threat comes with one complete detection in Splunk SPL, Microsoft KQL and Sigma, free for everyone; a free account adds daily TL Creds to unlock the rest. Paid plans add a larger daily allowance, correlation and the MCP server. Threadlinqs MCP server · View plans.
Free detection: SC-1000 Web Service Spawning Root Shell or Utility, CVE-2026-97180 Post-Exploitation (SPL)
Detects a shell, interpreter, download utility or account/cron management binary started as root by the WebConfig HTTP service or a common embedded web server. CVE-2026-97180 injected commands run as root on the controller OS, so this child-process pattern is the expected artifact. This is a hunting hypothesis from the advisory: no observed exploitation artifacts are published and the WebConfig process name is unverified.
- Languages: Splunk SPL, Microsoft KQL, Sigma
- ATT&CK: T1059, T1059.004, T1078, T1136.001, T1053.003
- Data sources: Sysmon for Linux (index=linux, sourcetype=sysmon:linux, EventID 1), DeviceProcessEvents (Defender for Endpoint on Linux), Sigma logsource product linux, category process_creation
- Severity: critical
- Confidence: medium
Splunk SPL
index=linux sourcetype="sysmon:linux" EventID=1 User=root
| where match(ParentImage, "(?i)(webconfig|lighttpd|nginx|httpd|uhttpd|mini_httpd|boa|php-fpm|php-cgi|[.]cgi)$")
| where match(Image, "(?i)/(ba|da|a|z|k)?sh$|/busybox$|/nc$|/ncat$|/telnet$|/wget$|/curl$|/python[0-9.]*$|/perl$|/useradd$|/adduser$|/chpasswd$|/crontab$")
| stats count min(_time) as first_seen values(Image) as child_images values(CommandLine) as command_lines by host ParentImage User
| convert ctime(first_seen)Microsoft KQL
DeviceProcessEvents
| where Timestamp > ago(24h)
| where AccountName == "root"
| where InitiatingProcessFileName matches regex @"(?i)^(webconfig|lighttpd|nginx|httpd|uhttpd|mini_httpd|boa|php-fpm|php-cgi)$" or InitiatingProcessCommandLine has "webconfig"
| where FileName in~ ("sh", "bash", "dash", "ash", "zsh", "ksh", "busybox", "nc", "ncat", "telnet", "wget", "curl", "python", "python3", "perl", "useradd", "adduser", "chpasswd", "crontab")
| project Timestamp, DeviceName, AccountName, InitiatingProcessFileName, InitiatingProcessCommandLine, FileName, ProcessCommandLine
| order by Timestamp descSigma
title: SC-1000 WebConfig Service Spawning Root Shell or Account/Cron Utility
id: c3d9a6f1-84be-4b27-a15c-0e6f5d92b7c4
status: experimental
description: Detects a shell, network utility or account/cron management binary launched as root by the SC-1000 WebConfig HTTP service or a common embedded web server, the expected artifact of CVE-2026-97180 command injection.
references:
- https://cert.pl/en/posts/2026/11/CVE-2026-97180/
- https://nvd.nist.gov/vuln/detail/CVE-2026-97180
author: Threadlinqs Team
date: 2026/11/25
tags:
- attack.execution
- attack.t1059
- attack.t1059.004
- attack.persistence
- attack.t1136.001
- attack.t1053.003
- attack.privilege-escalation
- attack.t1078
- cve.2026.97180
logsource:
category: process_creation
product: linux
detection:
selection_parent:
ParentImage|contains:
- 'webconfig'
- '/lighttpd'
- '/nginx'
- '/httpd'
- '/uhttpd'
- '/mini_httpd'
- '/boa'
- 'php-fpm'
- 'php-cgi'
selection_child:
Image|endswith:
- '/sh'
- '/bash'
- '/dash'
- '/ash'
- '/zsh'
- '/busybox'
- '/nc'
- '/ncat'
- '/telnet'
- '/wget'
- '/curl'
- '/python3'
- '/perl'
- '/useradd'
- '/adduser'
- '/chpasswd'
- '/crontab'
selection_user:
User: 'root'
condition: selection_parent and selection_child and selection_user
falsepositives:
- Vendor WebConfig CGI scripts that legitimately call /bin/sh for network or NTP configuration
- Firmware update or diagnostic functions invoked by administrators
level: critical
Known false positives:
- Vendor WebConfig CGI scripts that legitimately call sh for network or NTP configuration
- Administrator-triggered firmware update or diagnostic functions
Tuning notes: Confirm the real WebConfig process name on a lab SC-1000 and replace the ParentImage list. Baseline normal child processes for 7 days and allowlist exact CommandLine values from vendor scripts. Embedded controllers often cannot run Sysmon or an EDR agent, so forward auditd execve records through a collector and adapt the field names.
- CVE-2026-97180 SC-1000 WebConfig Command Injection via server Parameter (KQL) · unlock with TL Creds
- SC-1000 Web Service Spawning Root Shell or Utility, CVE-2026-97180 Post-Exploitation (KQL) · unlock with TL Creds
- SC-1000 Controller Outbound Internet Connections, Post-Exploitation C2 or Tool Transfer (KQL) · unlock with TL Creds
- CVE-2026-97180 SC-1000 WebConfig Command Injection via server Parameter (Sigma) · unlock with TL Creds
- SC-1000 Web Service Spawning Root Shell or Utility, CVE-2026-97180 Post-Exploitation (Sigma) · unlock with TL Creds
- SC-1000 Controller Root Reverse Shell or Download-and-Execute, Post-Exploitation C2 or Tool Transfer (Sigma) · unlock with TL Creds
- CVE-2026-97180 SC-1000 WebConfig Command Injection via server Parameter (SPL) · unlock with TL Creds
- SC-1000 Controller Outbound Internet Connections, Post-Exploitation C2 or Tool Transfer (SPL) · unlock with TL Creds
Indicators of compromise
As of 2026-11-25, Threadlinqs Intelligence tracks 11 indicators of compromise for TL-2026-6880.
Sample indicators (1 of 11)
- URL:
hxxps://cert[.]pl/en/posts/2026/11/CVE-2026-97180/
Defanged, TLP:CLEAR. Full set of 11 indicators: unlock with TL Creds.
Technical analysis
CVE-2026-97180 is an OS command injection (CWE-78) in WebConfig, the web-based configuration component of the ASSA ABLOY Seawing SC-1000 access-control controller family. Per CERT Polska, due to a lack of input sanitization a privileged attacker can inject shell metacharacters into the `server` parameter of an HTTP request, resulting in arbitrary command execution as the root user on the underlying operating system. The advisory names no URL path or endpoint.
All WebConfig versions before 1.5.14 are affected (NVD: versions from 0 up to, but not including, 1.5.14). The vendor fixed the issue in version 1.5.14. The vulnerability was reported to CERT Polska by Maciej Kucab and Michał Lipiński, and CERT Polska took part in coordinating disclosure. The vendor lists the issue as SEAWING-SA-2026-01 ("SC-1000 WebConfig - OS command injection") dated 2026-10-27; CERT Polska published its advisory and the CVE record on 2026-11-25.
Severity: the CNA (cvd@cert.pl) supplied a CVSS v4.0 base score of 9.4 (CRITICAL) with vector AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H. The high privilege requirement (PR:H) limits exposure to attackers who already hold privileged WebConfig credentials or sessions, but successful exploitation yields root on the controller with high impact on the vulnerable and subsequent systems. CISA's SSVC assessment in NVD (2026-11-25) records exploitation "none", automatable "no", technical impact "total".
The SC-1000 is described by the vendor as an intelligent group controller that manages access, security and output modules over CAN bus and network interfaces and runs a Linux operating system. A root compromise of such a controller could affect the physical-security system it manages; that downstream effect is an analyst inference and is not stated in the advisories.
Not established by any source: exploitation in the wild, a public proof of concept, CISA KEV listing, threat-actor attribution, malware, or network IOCs. The vendor advisory PDF (sections: Overview, Vulnerability description, Impact, Severity, CVSS vector, Affected versions and remediation) could not be text-extracted during research, so vendor-specific workarounds and the exact WebConfig network exposure are unverified. A separate vendor advisory, SEAWING-SA-2026-02 (SC 1000 Firmware legacy web interface remote code execution, CVE-2026-109618 and CVE-2026-109619), was published the same day; the sources do not say whether it is related to this issue.
MITRE ATT&CK techniques by tactic:
Execution
T1059 Command and Scripting Interpreter; T1059.004 Command and Scripting Interpreter: Unix Shell
Initial Access
T1078 Valid Accounts; T1190 Exploit Public-Facing Application
Privilege Escalation
Remediation
Patches
- WebConfig 1.5.14 (fixed version per CERT Polska and NVD)
Immediate actions
- Upgrade ASSA ABLOY Seawing SC-1000 WebConfig to version 1.5.14 or later
- Restrict network access to the WebConfig HTTP interface to trusted management hosts or a dedicated management VLAN
- Review and rotate privileged WebConfig accounts and audit who holds administrative access
Workarounds
- No vendor workaround is stated in the CERT Polska advisory; limit WebConfig reachability and privileged-account exposure until patched
Longer-term hardening
- Keep access-control controllers off general-purpose and internet-facing networks
- Log and monitor HTTP requests to controller management interfaces and alert on shell metacharacters in parameters
- Monitor Seawing product security advisories (psirt.seawing@assaabloy.com for reports)
Affected and fixed versions
- ASSA ABLOY — Seawing SC-1000 WebConfig
Vulnerable versions: All versions before 1.5.14
Fixed in: 1.5.14
Timeline
- The vendor advisory dated 2026-10-27 identifies WebConfig 1.5.14 as the fixed release; all earlier versions are listed as affected.
- Seawing lists advisory SEAWING-SA-2026-01 "SC-1000 WebConfig - OS command injection" (CVE-2026-97180, CWE-78); advisory SEAWING-SA-2026-02 (SC 1000 legacy web interface RCE, separate CVEs) is listed the same day.
- Seawing Security Advisory PDF v1.0 for SEAWING-SA-2026-01 carries a creation/modification date of 2026-11-06 in its document metadata.
- CISA coordinator SSVC entry (15:32 UTC) records exploitation none, automatable no, technical impact total; no in-the-wild exploitation reported.
- CVE-2026-97180 published in NVD (13:17 UTC) with a CNA-supplied CVSS v4.0 base score of 9.4 (CRITICAL) and status Received.
- CERT Polska publishes its advisory crediting Maciej Kucab and Michał Lipiński; version 1.5.14 identified as the fix and all earlier versions as affected.
Sources cited
- CERT Polska: Vulnerability in ASSA ABLOY Seawing SC-1000 WebConfig cert.pl · Advisory · 2026-11-25
- CVE Record CVE-2026-97180 CVE Program · Advisory · 2026-11-25
- NVD: CVE-2026-97180 (CVSS v4.0 9.4, CISA SSVC) NVD (NIST) · Advisory · 2026-11-25
- Seawing Product Security Advisories (SEAWING-SA-2026-01, SC-1000 WebConfig OS command injection) seawing.eu · Vendor report · 2026-10-27
- Seawing Security Advisory SEAWING-SA-2026-01 v1.0 (PDF) seawing.eu · Vendor report · 2026-10-27
- CWE-78: Improper Neutralization of Special Elements used in an OS Command MITRE · Research
- Seawing SC-1000 product family page seawing.eu · Vendor report
- CERT Polska Coordinated Vulnerability Disclosure cert.pl · Research
- Seawing Security Advisory SEAWING-SA-2026-02 v1.0 (SC 1000 legacy web interface RCE, separate CVEs) seawing.eu · Vendor report · 2026-10-27
Drafted by the Threadlinqs research pipeline from 9 sources; published ; last updated —.