Threat reportThreat IntelligenceTL-2026-6895

Bishop Fox icsScanner: Safe Active Vulnerability Scanning for ICS and OT Networks

MONITORING

Bishop Fox released icsScanner, an open-source (MIT) safety-first active and passive vulnerability scanner for ICS/OT protocols, with 250 promoted checks across 29 protocol families gated by fingerprinting, rate limiting, liveness polling and risk-flag tiers. A companion tool, detection-gen, generates Sigma, Splunk ESCU, Zeek and Suricata detection content from the same check metadata.

Key facts

IdentifiersTL-2026-6895
Also known asicsScanner, detection-gen
SeverityINFO
First disclosed
Affected productsVarious ICS/OT vendors ICS/OT devices exposing management or industrial protocols (Modbus, S7comm, OPC UA, DNP3, EtherNet/IP, IEC 104, etc.)
MalwareTriton
Toolsdetection-gen, icsScanner
MITRE ATT&CK techniquesT0846 Remote System Discovery, T1046 Network Service Discovery, T1078.001 Default Accounts, T1110 Brute Force, T1595.002 Vulnerability Scanning
MotivationUNKNOWN
Target sectorsenergy, manufacturing, critical-infrastructure, oil-and-gas, utilities
Target regionsGlobal
Detection rules9 (1 shown free)
Sources6 cited sources

Detection coverage

As of 2026-11-25, Threadlinqs Intelligence publishes 9 detection rule(s) for TL-2026-6895 across Splunk SPL, Microsoft KQL and Sigma, covering 11 indicator(s) of compromise. The whole corpus is readable without an account. Every threat comes with one complete detection in Splunk SPL, Microsoft KQL and Sigma, free for everyone; a free account adds daily TL Creds to unlock the rest. Paid plans add a larger daily allowance, correlation and the MCP server. Threadlinqs MCP server · View plans.

Free detection: icsScanner / icsscanner-web Execution on Endpoint

Detects Python launching icsscanner.py or icsscanner-web.py, or icsscanner run with --include-destructive (enables Adverse/Destructive checks: live login attempts and device writes). Unexpected execution outside an authorized assessment indicates unsanctioned OT scanning from that host.

  • Languages: Splunk SPL, Microsoft KQL, Sigma
  • ATT&CK: T1595.002, T1059.006
  • Data sources: sysmon, microsoft_defender_endpoint
  • Severity: medium
  • Confidence: high

Splunk SPL

index=windows sourcetype="XmlWinEventLog:Microsoft-Windows-Sysmon/Operational" EventCode=1 (Image="*\\python*.exe" OR Image="*\\py.exe") (CommandLine="*icsscanner.py*" OR CommandLine="*icsscanner-web.py*" OR (CommandLine="*icsscanner*" CommandLine="*--include-destructive*")) earliest=-24h
| eval risk_tier=if(like(CommandLine,"%--include-destructive%"),"adverse_destructive_enabled","default_safe_mode")
| stats count, min(_time) AS first_seen, max(_time) AS last_seen, values(CommandLine) AS command_lines BY host, User, ParentImage, risk_tier

Microsoft KQL

// Python executing icsScanner CLI or web UI
DeviceProcessEvents
| where Timestamp > ago(24h)
| where FileName startswith "python" or FileName =~ "py.exe"
| where ProcessCommandLine has_any ("icsscanner.py", "icsscanner-web.py") or (ProcessCommandLine has "icsscanner" and ProcessCommandLine has "--include-destructive")
| extend RiskTier = iff(ProcessCommandLine has "--include-destructive", "adverse_destructive_enabled", "default_safe_mode")
| project Timestamp, DeviceName, AccountName, FileName, ProcessCommandLine, InitiatingProcessFileName, RiskTier

Sigma

title: icsScanner or icsscanner-web Execution
id: 9c4e7a21-2d6b-4b39-a7f5-0e8d3c1b5a03
status: experimental
description: Detects Python executing icsscanner.py or icsscanner-web.py, or icsscanner invoked with --include-destructive which enables login attempts and device writes against OT devices
references:
    - https://bishopfox.com/blog/icsscanner-safe-vulnerability-scanning-ics-ot
    - https://github.com/BishopFox/icsScanner
author: Threadlinqs Team
date: 2026-11-25
tags:
    - attack.reconnaissance
    - attack.t1595.002
    - attack.execution
    - attack.t1059.006
logsource:
    category: process_creation
    product: windows
detection:
    selection_img:
        Image|contains: '\python'
    selection_cli:
        CommandLine|contains:
            - 'icsscanner.py'
            - 'icsscanner-web.py'
    selection_flag:
        CommandLine|contains|all:
            - 'icsscanner'
            - '--include-destructive'
    condition: selection_img and (selection_cli or selection_flag)
falsepositives:
    - Authorized OT assessments by the security team or a contracted assessor
    - Security research lab hosts
level: medium

Known false positives:

  • Authorized OT assessment by internal red team or contractor
  • Research or lab workstation

Tuning notes: Allow-list assessor hosts and accounts during approved windows. Escalate when --include-destructive appears or the host sits outside the assessor group. Linux/macOS hosts: use auditd/MDE Linux with the same command-line strings.

8 more detection rules (Splunk SPL, Microsoft KQL, Sigma) · unlock with TL Creds. Sign up free to unlock the detection rules or query them with the Threadlinqs MCP server (Purple and Gold in full, 2 calls a day on a free account)
  • OT Horizontal Discovery Sweep Across Multiple Hosts on Industrial Ports · unlock with TL Creds
  • SNMP Community String Guessing Against OT Device · unlock with TL Creds
  • icsScanner Output, Template Artifacts and Local Web UI Activity · unlock with TL Creds
  • Cisco Smart Install (TCP 4786) and TFTP Access to Network Devices · unlock with TL Creds
  • MQTT SUBSCRIBE to Sparkplug B Topics from Unexpected Client · unlock with TL Creds
  • Successful FTP Login with Factory-Default Account on OT Device · unlock with TL Creds
  • icsScanner-style Multi-Protocol OT Fingerprint Probing of a Single Target · unlock with TL Creds
  • OT Management-Plane Authentication Failure Burst (FTP/HTTP Default-Credential Guessing) · unlock with TL Creds

Indicators of compromise

As of 2026-11-25, Threadlinqs Intelligence tracks 11 indicators of compromise for TL-2026-6895.

11 indicators of compromise · unlock with TL Creds. Compare plans

Technical analysis

This is a dual-use assessment tool release, not an in-the-wild threat; no CVEs, threat actors or IOCs are named.

On 2026-11-25 Bishop Fox (authors Shad Malloy and Zoe Duncan) published a blog post and a GitHub repository (BishopFox/icsScanner, MIT license, Python 3.10+) for icsScanner, a scanner built for authorized assessment of ICS/OT networks (PLCs, protection relays, RTUs, SCADA). The post states the tool has 250 real (promoted) checks across 29 protocol families, plus 275 candidate findings that were researched but not promoted. Protocol families include Modbus, S7comm, OPC UA, PROFINET, EtherNet/IP, DNP3, IEC 104, SNMP, HTTP, FTP, TFTP, MQTT (with a Sparkplug B passive listener), Telnet, SSH, VNC, MSSQL, PCOM/TCP, InduSoft agent protocol, Red Lion Crimson, GE GeoSCADA, SECS/GEM HSMS, Mitsubishi MELSEC SLMP, Omron FINS, LS Electric XGT, Cisco Smart Install, Franklin Fueling, Veeder-Root ATG, Opto 22 OptoMMP and Robotis RoboPlus Motion.

Safety design. Fingerprint gating means no check runs unless vendor, product or a live protocol-identity check first confirms a match; the authors disclose a bug in which the gate was declared at load time but not enforced at scan time, so checks ran unconditionally for a milestone before it was fixed. Two independent runtime risk flags exist: Adverse (login attempts; 210 checks) and Destructive (device write or confirmed lockout; 10 checks); 30 checks need no flag. The default reports only fingerprint-confirmed results. The engine polls liveness before and after checks that could degrade a connection and aborts a target's remaining queue if it does not recover. Rate limiting has a global cap and a per-target cap. Confidence is capped at low unless an exact version match or demonstrated behavior exists. A separate safety-critical tier (9 tools) is unreachable from the CLI or web UI, uses a zero-network-I/O plan step that records target, exact bytes and a random expiring confirmation phrase, and requires a separate interactive confirmation; breaker open/close commands on protection relays were deliberately omitted. Disclosure posture of promoted checks: 249 public, 1 disclosed-fixed, 0 disclosed-pending-fix. Vulnerability feed integrations: CISA CSAF 2.0, Japan's MyJVN, ENISA EUVD and the ICS Advisory Project.

The README describes active scanning of explicit, authorized single-host targets (never CIDR ranges) and passive discovery from SPAN/TAP or pcap (including Zeek logs and Malcolm integration) that transmits nothing, except that the Sparkplug passive path sends an MQTT SUBSCRIBE. Most checks target factory-default credentials and insecure defaults. The web UI binds 127.0.0.1:8807 by default and has no authentication. detection-gen generates Sigma, Splunk ESCU, Suricata and Zeek signature content plus an ATT&CK-for-ICS policy from the check detection hints, using narrow (exact probe), broad (variations) and absent (no rule; rate-based or structural trigger) patterns.

Defensive relevance. The post references Triton/TRISIS/HatMan (discovered December 2017 on Triconex safety instrumented systems at a Saudi petrochemical plant) as background. Because the tool automates default-credential and known-vulnerability probing against OT management interfaces, defenders should treat its network footprint as a dual-use scanning signature: unexpected scans or login attempts against management planes from non-authorized hosts warrant investigation. Defensive guidance from the post: segment the management plane (web, Telnet, FTP, SSH should not be reachable from general-purpose networks), change factory credentials, disable unused management services, inventory by fingerprint rather than port, and monitor the management plane for authentication attempts. No in-the-wild malicious use of icsScanner is reported in any source.

MITRE ATT&CK techniques by tactic:

Discovery

T0846 Remote System Discovery; T1046 Network Service Discovery

Initial Access

T1078.001 Default Accounts

Credential Access

T1110 Brute Force

Reconnaissance

T1595.002 Vulnerability Scanning

Remediation

Patches

  • No CVEs named; apply vendor firmware updates per CISA CSAF/ICS advisories for deployed OT devices

Immediate actions

  • Restrict reachability of ICS/OT management interfaces (web, Telnet, FTP, SSH, VNC, SNMP) to dedicated management networks
  • Change factory-default credentials on PLCs, relays, RTUs and HMIs
  • Disable unused management services on OT devices

Workarounds

  • If scanning production OT, keep Adverse and Destructive risk flags off by default and use passive discovery where possible

Longer-term hardening

  • Inventory OT assets by device fingerprint rather than by port
  • Monitor the management plane for authentication attempts and unexpected scanning
  • Deploy passive OT network monitoring (e.g. Zeek/ICSNPP, Suricata, Malcolm) with detections for reconnaissance and default-credential activity
  • Run authorized assessments only against devices you own or have written permission to test, preferring fingerprint-gated, rate-limited tooling

Affected and fixed versions

  • Various ICS/OT vendors — ICS/OT devices exposing management or industrial protocols (Modbus, S7comm, OPC UA, DNP3, EtherNet/IP, IEC 104, etc.)

Timeline

  • Triton/TRISIS malware discovered on Triconex safety instrumented systems at a Saudi petrochemical plant (December 2017), found after a coding error tripped a plant shutdown; referenced as background in the Bishop Fox post.
  • CISA published MAR-17-352-01 (HatMan - Safety System Targeted Malware) describing the Triton/TRISIS malware.
  • Bishop Fox dated its prior-art sweep of existing ICS scanners (Nessus, Nuclei, Metasploit, nmap NSE, geeknik/scada-scanner) in the repository lab notes.
  • Item added to the Threadlinqs platform as an INFO-level monitoring item: dual-use OT assessment tool, no in-the-wild exploitation, CVEs or IOCs reported.
  • BishopFox/icsScanner GitHub repository (MIT, Python 3.10+) observed with 1 commit on main, no releases, 0 stars; detection-gen companion generates Sigma, Splunk ESCU, Zeek and Suricata content.
  • Bishop Fox published the icsScanner blog post: 250 promoted checks, 29 protocol families, fingerprint gating, risk-flag tiers and a safety-critical tier.

Sources cited

Drafted by the Threadlinqs research pipeline from 6 sources; published ; last updated —.

Threadlinqs Intelligence — Real-Time Threat Detection Platform

// threat_feed
$ sort --newest
Showing all threats

Live intelligence console

Threat level

Latest Threats