Threat reportVulnerabilityTL-2026-4460
Multiple vulnerabilities in boneIO Black and black_debian_images, including unauthenticated Node-RED RCE (CVE-2026-77052 through CVE-2026-77062)
CERT Polska disclosed 11 vulnerabilities on 2026-10-26 in the boneIO Black DIN-rail home-automation controller (boneIO app) and its black_debian_images firmware. The flaws include an unauthenticated Node-RED instance enabling remote code execution, authentication disabled by default, cleartext credentials, shared default MQTT credentials and passwordless sudo/docker privileges.
Key facts
Detection coverage
As of 2026-10-26, Threadlinqs Intelligence publishes 9 detection rule(s) for TL-2026-4460 across Splunk SPL, Microsoft KQL and Sigma, covering 14 indicator(s) of compromise. The whole corpus is readable without an account. Every threat comes with one complete detection in Splunk SPL, Microsoft KQL and Sigma, free for everyone; a free account adds daily TL Creds to unlock the rest. Paid plans add a larger daily allowance, correlation and the MCP server. Threadlinqs MCP server · View plans.
Free detection: boneIO Black Unauthenticated Node-RED Admin API Flow Deployment (CVE-2026-77052) — Exploitation
Detects write requests to the Node-RED Admin API exposed at /nodered/ behind Caddy on boneIO Black controllers (CVE-2026-77052, CWE-306). Deploying a flow through POST /nodered/flows lets an adjacent-network attacker run arbitrary system commands via exec nodes as the boneio account, which CVE-2026-77055 then turns into root. No authentication is required on versions 1.3.0 to before 1.6.0, so any POST/PUT/DELETE to the flow, node, settings or token endpoints from a host other than the administrator workstation is suspicious.
- Languages: Splunk SPL, Microsoft KQL, Sigma
- ATT&CK: T1190, T1059.004
- Data sources: caddy_access_logs, web_proxy_logs
- Severity: critical
- Confidence: high
Splunk SPL
index=web sourcetype="caddy:json" "/nodered/"
| eval uri='request.uri', method='request.method', src_ip='request.remote_ip', req_host='request.host'
| where match(uri, "(?i)^/nodered/(flows?|nodes|settings|auth/token)") AND method IN ("POST","PUT","DELETE")
| stats count AS requests earliest(_time) AS first_seen latest(_time) AS last_seen values(uri) AS uris values(status) AS http_status BY src_ip, req_host
| convert ctime(first_seen) ctime(last_seen)
| sort - requestsMicrosoft KQL
CommonSecurityLog
| where TimeGenerated > ago(24h)
| where RequestURL has "/nodered/"
| where RequestMethod in~ ("POST", "PUT", "DELETE")
| where RequestURL matches regex @"(?i)/nodered/(flows?|nodes|settings|auth/token)"
| summarize Requests = count(), FirstSeen = min(TimeGenerated), LastSeen = max(TimeGenerated), Urls = make_set(RequestURL, 20) by SourceIP, DestinationIP, DestinationPort
| project FirstSeen, LastSeen, SourceIP, DestinationIP, DestinationPort, Requests, Urls
| order by Requests descSigma
title: boneIO Black Node-RED Admin API Flow Deployment Without Authentication
id: a1b2c3d4-4460-4a01-8b01-446000000001
status: experimental
description: Detects POST/PUT/DELETE requests to the Node-RED Admin API under /nodered/ on boneIO Black controllers (CVE-2026-77052), which allow unauthenticated flow deployment and OS command execution.
references:
- https://cert.pl/en/posts/2026/10/CVE-2026-77052/
- https://nvd.nist.gov/vuln/detail/CVE-2026-77052
author: Threadlinqs Team
date: 2026/10/26
tags:
- attack.initial-access
- attack.t1190
- attack.execution
- attack.t1059.004
- cve.2026.77052
logsource:
category: webserver
detection:
selection_uri:
c-uri|contains:
- '/nodered/flow'
- '/nodered/nodes'
- '/nodered/settings'
- '/nodered/auth/token'
selection_method:
cs-method:
- 'POST'
- 'PUT'
- 'DELETE'
filter_local:
c-ip:
- '127.0.0.1'
- '::1'
condition: selection_uri and selection_method and not filter_local
falsepositives:
- Administrator deploying Node-RED flows from a management workstation
- Home Assistant or provisioning tooling that legitimately pushes flows
level: high
Known false positives:
- Administrator deploying Node-RED flows from a management workstation
- Provisioning or Home Assistant tooling that legitimately pushes flows to Node-RED
Tuning notes: Allowlist the management workstation IPs in the where clause. Change index/sourcetype to match your Caddy JSON log onboarding. Version 1.6.0 requires authentication, so after patching, a 401 status in http_status can be excluded to cut noise.
- [indicator] Black Unauthenticated [indicator] Retrieval Exposing Cleartext Passwords (CVE-2026-77054) — Exploitation · unlock with TL Creds
- [indicator] Sudoers Drop-in Creation or Symlink Race (CVE-2026-77059) — Post-Exploitation · unlock with TL Creds
- [indicator] Controller SSH and Web Login Brute Force Without Rate Limiting (CVE-2026-77057) — Credential Access · unlock with TL Creds
- [indicator] Black Cross-Site Request Forgery Device Control / Reboot (CVE-2026-77058) — Exploitation · unlock with TL Creds
- [indicator] Local Read of World-Readable Mosquitto Password File (CVE-2026-77060) — Post-Exploitation · unlock with TL Creds
- [indicator] Unauthenticated API Reconnaissance of Logs, Version and Documentation (CVE-2026-77061) — Discovery · unlock with TL Creds
- [indicator] Service Account Passwordless Sudo to Root Shell or Privileged Docker (CVE-2026-77055) — Post-Exploitation · unlock with TL Creds
- [indicator] Mosquitto Broker Connection From Non-Local Host With Shared Default Credentials (CVE-2026-77056) — C2 / Lateral Movement · unlock with TL Creds
Indicators of compromise
As of 2026-10-26, Threadlinqs Intelligence tracks 14 indicators of compromise for TL-2026-4460.
Technical analysis
All are fixed in version 1.6.0.
CERT Polska (CVD coordinator) published an advisory on 2026-10-26, credited to Mateusz Włodarczak (s3ga), covering eleven CVEs in boneIO Black, a DIN-rail home-automation controller running Debian with Caddy, Mosquitto (MQTT), Node-RED and Home Assistant integration. The web UI is served at https://<controller IP>:8443. NVD records were published the same day with CVSS v4.0 scores.
Remote / adjacent-network attack surface: CVE-2026-77052 (CWE-306, CVSS 4.0 8.7 HIGH) exposes an unauthenticated Node-RED instance at /nodered/ behind a Caddy reverse proxy; the Node-RED Admin API allows deploying flows that run arbitrary system commands, giving unauthenticated attackers on the local network remote code execution (affected 1.3.0 up to 1.6.0). CVE-2026-77053 (CWE-306, 8.7 HIGH) ships with authentication disabled by default and an API listening on all interfaces, allowing full device control including operating connected physical circuits (relays, blinds, gates). CVE-2026-77061 (CWE-306, 5.3 MEDIUM) leaves several API endpoints unauthenticated, leaking system logs, firmware version, serial number, MQTT username, configuration file listings and API documentation. CVE-2026-77054 (CWE-312, 6.9 MEDIUM) stores passwords in cleartext and returns the full configuration, including sub-service passwords, from GET /api/config; combined with CVE-2026-77053 an unauthenticated adjacent attacker can harvest all passwords. CVE-2026-77056 (CWE-1392, 7.1 HIGH) ships the Mosquitto MQTT broker with the same publicly documented default credentials on all devices, giving full read/write on the broker, control of relays, blinds and gates, and the ability to inject fake entities into a linked Home Assistant. CVE-2026-77057 (CWE-307, 2.3 LOW) has no rate limiting on web login or SSH and no password complexity enforcement. CVE-2026-77058 (CWE-352, 5.1 MEDIUM) lacks CSRF tokens and Origin/Referer validation, allowing a malicious page visited by an internal user to reboot the controller, switch relays, operate gates and blinds, or terminate the device; the default-disabled authentication amplifies the risk. CVE-2026-77062 (CWE-1021) lacks clickjacking protections (frame/iframe restrictions); an NVD score could not be retrieved at research time.
Local privilege-escalation surface: CVE-2026-77055 (CWE-266, 9.3 CRITICAL, local) gives the boneio service account full passwordless sudo and docker group membership, so a compromised boneio account (for example via the Node-RED RCE) becomes root. CVE-2026-77059 (CWE-367, 8.8 HIGH, local) is a TOCTOU race in create_timedatectl_sudoers_file() in boneio/webui/routes/timezone_sudoers.py that allows sudoers rule injection via content substitution or symlink attacks on a predictable filename, leading to root. CVE-2026-77060 (CWE-732, 6.8 MEDIUM, local) leaves /etc/mosquitto/passwd world-readable so any local user can read MQTT password hashes and mount offline dictionary attacks.
Chaining the adjacent-network flaws (77053 / 77052 / 77054) with the local ones (77055 / 77059) yields unauthenticated network-adjacent root on the controller, a pivot point into the building network and Home Assistant. Remediation in 1.6.0: enforced admin account creation and role-based access control, authentication on all routes with API docs disabled, salted scrypt password hashes with secrets no longer returned by the API, per-device generated MQTT passwords at first boot, removal of the sudoers rules and docker group membership with privileged operations via restricted helpers verifying Ed25519 signatures, web-login rate limiting per source and account, 8-character minimum password and SSH limited to three attempts per connection. Devices below 1.2.0 require re-flashing rather than in-place upgrade.
Source caveats: the CERT Polska page lists 1.6.0 both as fixed and within the affected range; NVD states affected versions are prior to 1.6.0, which this record follows. NVD labels CWE-307 for CVE-2026-77057 with a different title (UI layer restriction); CERT Polska's CWE-307 (excessive authentication attempts) matches the described behavior and is used. The sources do not state a public PoC, in-the-wild exploitation, CISA KEV listing, threat actor or network IOCs. CVE-2026-77052 / CVE-2026-77053 are the headline scores; the record's CVSS is the 4.0 score and vector from the NVD entry for CVE-2026-77053.
MITRE ATT&CK techniques by tactic:
Execution
T1059.004 Command and Scripting Interpreter: Unix Shell
Initial Access
T1078.001 Valid Accounts: Default Accounts; T1190 Exploit Public-Facing Application
Discovery
T1082 System Information Discovery
Credential Access
T1110.001 Brute Force: Password Guessing; T1110.002 Brute Force: Password Cracking; T1552.001 Unsecured Credentials: Credentials In Files
Impact
Privilege Escalation
T1548.003 Abuse Elevation Control Mechanism: Sudo and Sudo Caching; T1611 Escape to Host
Remediation
Patches
- boneIO 1.6.0 (CERT Polska advisory, NVD CVE-2026-77052 to CVE-2026-77062)
Immediate actions
- Upgrade boneIO Black / black_debian_images to version 1.6.0 or later (devices below 1.2.0 must be re-flashed)
- Complete first-run administrator account setup so authentication is enforced on all API routes
- Rotate all MQTT, web panel and SSH passwords and any credentials previously returned by /api/config
- Restrict access to the controller (https port 8443, /nodered/, MQTT 1883) to a dedicated management VLAN
Workarounds
- Do not expose the controller to untrusted networks while authentication is disabled
- Block /nodered/ at a reverse proxy or firewall until upgraded
- Do not browse untrusted sites from hosts on the same network as an unpatched controller (CSRF/clickjacking)
Longer-term hardening
- Isolate building-automation controllers from user and internet-facing networks
- Monitor MQTT broker and Home Assistant for unexpected publishers or injected entities
- Alert on new sudoers.d files and docker group changes on controllers
Affected and fixed versions
- boneIO — boneIO (app_black, boneIO Black web UI/API)
Vulnerable versions: 1.0.0 to before 1.6.0 (CVE-2026-77053); 1.2.0 to before 1.6.0 (CVE-2026-77054, 77057, 77058, 77061, 77062); 1.3.0 to before 1.6.0 (CVE-2026-77052, 77059)
Fixed in: 1.6.0 - boneIO — black_debian_images
Vulnerable versions: 1.2.0 to before 1.6.0 (CVE-2026-77055, 77056, 77060)
Fixed in: 1.6.0
Timeline
- Advisory and NVD records state no public PoC and no in-the-wild exploitation; no KEV listing identified
- Local privilege-escalation flaws CVE-2026-77055 (9.3 CRITICAL) and CVE-2026-77059 (8.8 HIGH) rated; chaining with the network RCE gives root on the controller
- CVE-2026-77052 (unauthenticated Node-RED /nodered/ RCE) and CVE-2026-77053 (authentication disabled by default) rated CVSS 4.0 8.7 HIGH, adjacent-network attack vector
- boneIO 1.6.0 identified as the fixed version: enforced admin setup and RBAC, scrypt password hashing, per-device MQTT passwords, removal of passwordless sudo/docker membership, login rate limiting
- NVD published records for the CVEs with CVSS v4.0 scores ranging from 2.3 (CVE-2026-77057) to 9.3 (CVE-2026-77055)
- CERT Polska published a coordinated-disclosure advisory covering 11 vulnerabilities (CVE-2026-77052 to CVE-2026-77062) in boneIO and black_debian_images, credited to Mateusz Włodarczak (s3ga)
Sources cited
- CERT Polska: Vulnerabilities in boneIO products cert.pl · Advisory · 2026-10-26
- NVD: CVE-2026-77052 NVD (NIST) · Advisory · 2026-10-26
- NVD: CVE-2026-77053 NVD (NIST) · Advisory · 2026-10-26
- NVD: CVE-2026-77054 NVD (NIST) · Advisory · 2026-10-26
- NVD: CVE-2026-77055 NVD (NIST) · Advisory · 2026-10-26
- NVD: CVE-2026-77056 NVD (NIST) · Advisory · 2026-10-26
- NVD: CVE-2026-77059 NVD (NIST) · Advisory · 2026-10-26
- boneIO Black documentation boneio.eu · Vendor report · 2026-10-26
- CERT Polska Coordinated Vulnerability Disclosure policy cert.pl · Research · 2026-10-26
Previous and next in vulnerability
Drafted by the Threadlinqs research pipeline from 9 sources; published ; last updated —.