Activity timeline
T0859 first appeared in tracked threats on and was most recently reported on . The busiest month was 2026-10 with 5 reports, and 11 of the 12 threats were reported in the twelve months to 2026-10.
How adversaries use it
T0859 Valid Accounts is catalogued by MITRE ATT&CK under the Persistence (ICS) and Lateral Movement (ICS) tactics in the ICS matrix. Threadlinqs maps 12 of 2892 tracked threats (0.4%) to it; by severity that is 6 critical, 5 high, 1 medium.
Threats that use T0859 most often also use T1059 Command and Scripting Interpreter (8 threats), T1078 Valid Accounts (8 threats), T1190 Exploit Public-Facing Application (6 threats), T0807 Command-Line Interface (4 threats), T0819 Exploit Public-Facing Application (4 threats). These are the techniques an intrusion set tends to chain with it, so they are the natural next places to look when it is observed.
5 tracked threat actors appear in the threats that use T0859; the most frequent are APT44 (2), Sandworm (2), Cyber Av3ngers (1), NoName057(16) (1), Static Tundra (1).
Threat actors using it
Tracked threats
12 tracked threats use T0859.
- CVE-2026-25721 - Copeland XWEB Pro OS Command Injection (Authenticated RCE) via API V1 Restore Actionhigh
- CVE-2026-25196: Copeland XWEB Pro OS Command Injection via Wi-Fi SSID/Password Fields (Authenticated RCE)high
- CVE-2026-3037: OS Command Injection in Copeland XWEB Pro (MBird SMS service) enabling authenticated RCEhigh
- CVE-2026-21660: Hardcoded Credentials in Johnson Controls Frick Controls Quantum HD Industrial Refrigeration…medium
- Exposed Industrial Controllers (Rockwell MicroLogix 1100/1400, Unitronics) Hijacked in July 2026 Campaign…high
- AI-Generated Exploit Scripts Targeting Siemens S7 Series PLCs in U.S. Critical Infrastructurehigh
- AI-Powered Attacks Targeting Siemens S7 Series PLCs in U.S. Critical Infrastructurecritical
- Siemens Ruggedcom ROX II Three-Stage Zero-Day Exploit Chain (CVE-2025-40948, CVE-2025-40947, CVE-2025-40949)critical
- Iranian IRGC CyberAv3ngers APT Campaign Targeting Rockwell/Allen-Bradley PLCs (CISA AA26-097A)critical
- Pro-Russia Hacktivists (CARR/Z-Pentest/NoName057/Sector16) — GRU Unit 74455-Linked OT/ICS Attacks on US and…critical
- Default ICS Credentials Exploited in Destructive Attack on Polish Energy Facilitiescritical
- CVE-2024-49775: Unauthenticated Heap-Based Buffer Overflow in Siemens User Management Component (UMC)…critical
Detection coverage
Threadlinqs maintains 21 detection rules mapped to T0859 (SPL 7, KQL 8, Sigma 6). Rule content is available to Blue tier accounts and above; this page shows counts only.