Skip to navigation

Threat reportICS/SCADATL-2026-6885

US Water Sector Supply-Chain Exposure: Unreported Exploited ICS Vulnerabilities and Internet-Exposed PLCs/Cellular Modems Targeted by Iranian-Affiliated Actors (Securin Water Supply Chain Watch, CISA AA26-097A)

highACTIVE

Securin's Water Supply Chain Watch index of 236 vendors serving US water and wastewater systems found almost twice as many vulnerabilities as public records, including 20 exploited flaws absent from CISA KEV. Real-world intrusions, including July 2026 activity against 100+ internet-exposed water systems and the Iranian-affiliated PLC campaign in CISA AA26-097A, rely mainly on exposed controllers behind cellular modems and default or missing credentials rather than software bugs. First disclosed .

Key facts

IdentifiersTL-2026-6885, CVE-2017-16740
Also known asWater Supply Chain Watch, AA26-097A, July 2026 US water system intrusions
SeverityHIGH
First disclosed
EPSSCVE-2017-16740: 7.2% (94.3th percentile)
Affected productsRockwell Automation Allen-Bradley CompactLogix, Micro850, MicroLogix 1400 PLCs; Schneider Electric Modicon M340 / BMX P34 PLCs; Siemens SIMATIC S7-1200 series PLCs; Unitronics Vision series PLCs with HMI; Various Cellular modems/routers fronting PLCs (Dropbear SSH on port 22)
Weaknesses (CWE)CWE-798, CWE-306
AttributionIranian-affiliated APT actors (medium confidence)
Nation-state nexusIran
ToolsDropbear SSH, EcoStruxure Control Expert, Studio 5000 Logix Designer, TIA Portal
MITRE ATT&CK techniquesT1219 Remote Access Tools, T1565 Data Manipulation
MotivationDESTRUCTION
Target sectorswater and wastewater, government services and facilities, energy, industrial control systems
Target regionsunited states of america
Detection rules9 (1 shown free)
Sources12 cited sources

Detection coverage

As of 2026-11-25, Threadlinqs Intelligence publishes 9 detection rule(s) for TL-2026-6885 across Splunk SPL, Microsoft KQL and Sigma, covering 25 indicator(s) of compromise. The whole corpus is readable without an account. Every threat comes with one complete detection in Splunk SPL, Microsoft KQL and Sigma, free for everyone; a free account adds daily TL Creds to unlock the rest. Paid plans add a larger daily allowance, correlation and the MCP server. Threadlinqs MCP server · View plans.

Free detection: AA26-097A Internet-Sourced Access to PLC Ports (EtherNet/IP, S7comm, Modbus) — Exploitation

Flags allowed sessions from non-RFC1918 sources to TCP 44818, 2222, 102 and 502 and tags matches to AA26-097A actor IPs. Reflects TL-2026-6885 behaviour where Iranian-affiliated actors reach internet-exposed Rockwell, Schneider and Siemens PLCs, often behind cellular modems with default or missing credentials; also surfaces exposure to CVE-2017-16740 (Modbus/TCP buffer overflow).

  • Languages: Splunk SPL, Microsoft KQL, Sigma
  • ATT&CK: T1190, T1133, T1078.001
  • Data sources: pan:traffic, firewall
  • Severity: high
  • Confidence: high

Splunk SPL

index=firewall sourcetype="pan:traffic" action=allowed dest_port IN (44818,2222,102,502) earliest=-24h | where NOT (cidrmatch("10.0.0.0/8",src_ip) OR cidrmatch("172.16.0.0/12",src_ip) OR cidrmatch("192.168.0.0/16",src_ip)) | eval aa26_097a_ioc=if(in(src_ip,"185.82.73.175","141.11.164.153","175.110.121.42","175.110.121.39","175.110.121.41","175.110.121.107","192.142.54.79","84.200.205.165","185.225.17.225","79.133.46.209","88.80.150.199","88.80.150.200","88.80.150.202","185.82.73.162","185.82.73.164","185.82.73.165","185.82.73.167","185.82.73.168","185.82.73.170","185.82.73.171","135.136.1.133"),1,0), ics_protocol=case(dest_port=44818 OR dest_port=2222,"EtherNet/IP-CIP",dest_port=102,"S7comm",dest_port=502,"Modbus/TCP",true(),"other") | stats count AS sessions sum(bytes_out) AS bytes_to_plc sum(bytes_in) AS bytes_from_plc dc(dest_ip) AS plcs_touched values(dest_ip) AS plc_targets values(ics_protocol) AS protocols max(aa26_097a_ioc) AS ioc_hit min(_time) AS first_seen max(_time) AS last_seen by src_ip dest_port | eval threat="TL-2026-6885 AA26-097A internet-to-PLC access (T1190/T1133/T1078.001; CVE-2017-16740 Modbus/502 exposure)" | convert ctime(first_seen) ctime(last_seen) | sort - ioc_hit - sessions

Microsoft KQL

let aa26_097a_iocs = dynamic(['185.82.73.175', '141.11.164.153', '175.110.121.42', '175.110.121.39', '175.110.121.41', '175.110.121.107', '192.142.54.79', '84.200.205.165', '185.225.17.225', '79.133.46.209', '88.80.150.199', '88.80.150.200', '88.80.150.202', '185.82.73.162', '185.82.73.164', '185.82.73.165', '185.82.73.167', '185.82.73.168', '185.82.73.170', '185.82.73.171', '135.136.1.133']);
CommonSecurityLog
| where TimeGenerated > ago(24h)
| where DeviceAction in~ ('allow', 'accept', 'allowed', 'permit')
| where DestinationPort in (44818, 2222, 102, 502)
| where not(ipv4_is_private(SourceIP))
| extend IocMatch = SourceIP in (aa26_097a_iocs),
    IcsProtocol = case(DestinationPort in (44818, 2222), 'EtherNet/IP-CIP', DestinationPort == 102, 'S7comm', DestinationPort == 502, 'Modbus/TCP', 'other')
| summarize Sessions = count(), PlcTargets = make_set(DestinationIP, 50), FirstSeen = min(TimeGenerated), LastSeen = max(TimeGenerated), IocHit = max(toint(IocMatch)) by SourceIP, DestinationPort, IcsProtocol, DeviceVendor
| project FirstSeen, LastSeen, SourceIP, DestinationPort, IcsProtocol, Sessions, PlcTargets, IocHit, DeviceVendor
| order by IocHit desc, Sessions desc

Sigma

title: Internet-Sourced Access to PLC Ports or AA26-097A Actor IP (TL-2026-6885)
id: 6a1f3c52-8d47-4b9e-a2c1-5e0b7d914a01
status: experimental
description: Detects allowed firewall sessions from non-RFC1918 sources to PLC protocol ports 44818, 2222, 102 and 502 (EtherNet/IP, S7comm, Modbus/TCP), or any session from AA26-097A actor-associated IPs. Matches the exposed-PLC access pattern used by Iranian-affiliated actors against water systems and the exposure relevant to CVE-2017-16740.
references:
    - https://www.cisa.gov/news-events/cybersecurity-advisories/aa26-097a
    - https://www.forescout.com/blog/ot-security-analysis-exposed-devices-attacked-in-us-water-systems/
    - https://www.securin.io/reports/water-supply-chain-watch
author: Threadlinqs Team
date: 2026/11/25
tags:
    - attack.initial-access
    - attack.t1190
    - attack.t1133
    - attack.persistence
    - attack.t1078.001
    - cve.2017.16740
logsource:
    category: firewall
detection:
    selection_ports:
        dst_port: [44818, 2222, 102, 502]
    filter_internal_src:
        src_ip|cidr: ['10.0.0.0/8', '172.16.0.0/12', '192.168.0.0/16']
    selection_ioc:
        src_ip: ['185.82.73.175', '141.11.164.153', '175.110.121.42', '175.110.121.39', '175.110.121.41', '175.110.121.107', '192.142.54.79', '84.200.205.165', '185.225.17.225', '79.133.46.209', '88.80.150.199', '88.80.150.200', '88.80.150.202', '185.82.73.162', '185.82.73.164', '185.82.73.165', '185.82.73.167', '185.82.73.168', '185.82.73.170', '185.82.73.171', '135.136.1.133']
    condition: (selection_ports and not filter_internal_src) or selection_ioc
falsepositives:
    - Authorized remote vendor support or integrator access to PLCs
    - Cloud or MSSP monitoring platforms polling OT assets
level: high

Known false positives:

  • Authorized vendor or integrator remote support reaching PLCs from public addresses
  • Managed-service or SCADA hosting providers polling OT sites through carrier NAT

Tuning notes: Add known vendor and integrator source IPs to an allowlist; adjust index/sourcetype and field names (src_ip, dest_port, bytes_out) to your firewall; refresh the AA26-097A IP list from the CISA STIX feed and vet before blocking.

8 more detection rules (Splunk SPL, Microsoft KQL, Sigma) · unlock with TL Creds. Sign up free to unlock the detection rules or query them with the Threadlinqs MCP server (Purple and Gold in full, 2 calls a day on a free account)
  • Sentinel: Internet-Sourced Sessions to PLC Ports or AA26-097A IPs — Exploitation · unlock with TL Creds
  • Sentinel: PLC Engineering Software Connecting to Public IP — Post-Exploitation · unlock with TL Creds
  • Sentinel: Dropbear SSH Login from Public IP on Cellular Modem Syslog — C2 / Remote Access · unlock with TL Creds
  • Sigma: Internet-Sourced Access to PLC Ports or AA26-097A IP — Exploitation · unlock with TL Creds
  • Sigma: PLC Engineering Software to Public IP on ICS Ports — Post-Exploitation · unlock with TL Creds
  • Sigma: Dropbear SSH Success Involving AA26-097A Actor IP — C2 / Remote Access · unlock with TL Creds
  • PLC Project Download/Upload or Stop Command from External Source — Post-Exploitation · unlock with TL Creds
  • External SSH to Dropbear Cellular Modem Fronting PLC — C2 / Remote Access · unlock with TL Creds

Indicators of compromise

As of 2026-11-25, Threadlinqs Intelligence tracks 25 indicators of compromise for TL-2026-6885.

Sample indicators (3 of 25)

  • IP address: 185.82.73[.]175
  • IP address: 141.11.164[.]153
  • IP address: 175.110.121[.]42

Defanged, TLP:CLEAR. Full set of 25 indicators: unlock with TL Creds.

25 indicators of compromise · unlock with TL Creds. Compare plans

Technical analysis

Securin's Water Supply Chain Watch (reported by The Register on 2026-11-25) examined 236 technology vendors supplying US drinking water, wastewater and industrial water systems, comparing CISA, EPA, FBI and WaterISAC data (CISA advisory data through 2026-11-20, KEV entries through 2026-11-23). The federal government has issued 4,014 ICS security advisories and cataloged 1,792 known-exploited vulnerabilities; Securin's index found almost twice as many vulnerabilities as public records identified, including 20 exploited flaws that are not in CISA KEV. Federal water advisories reached their highest level this year since 2020. Five vendors account for 191 of 376 water-tagged advisories: Rockwell Automation (58), Advantech (48), Schneider Electric (35), Siemens (26) and ABB (24). Advantech had the most critical-rated vulnerabilities but none appear in KEV. Securin notes that advisory volume is not a reliable predictor of attacks: Unitronics had only 2 water-tagged advisories, yet at least 75 of its controllers were compromised between November 2023 and January 2024 through default or missing passwords.

Exposure is the dominant risk. Securin counted 791 Rockwell MicroLogix 1400 controllers across US industries exposed to the internet as of 2026-11-17. Forescout research (August 2026 scan) reported 4,407 exposed Rockwell controllers worldwide, 2,844 in the US, with about 70% of US-based devices in large mobile carrier networks reached via cellular routers; 22 internet-facing Rockwell PLCs were found in cities hit by recent water-utility attacks, 19 of them on the same carrier network, and 19 of the 22 ran firmware susceptible to CVE-2017-16740 (Modbus TCP buffer overflow). Forescout could not confirm those specific devices were compromised and stated the publicly described effects could be achieved without an exploit, because attackers can change IP addresses and passwords on reachable controllers. Poorly secured cellular modems, often installed by third-party contractors and undocumented, are a recurring entry point.

CISA, FBI, NSA, EPA, DOE, CNMF and Treasury advisory AA26-097A (published 2026-04-07, updated 2026-07-22) describes Iranian-affiliated APT actors accessing internet-facing PLCs (Rockwell/Allen-Bradley CompactLogix and Micro850, Schneider Electric BMX P34/Modicon M340, Siemens S7-1200, and potentially any exposed PLC) from foreign-based and leased third-party hosted IP addresses, using the vendors' own programming software (Studio 5000 Logix Designer, EcoStruxure Control Expert, TIA Portal) on ports 44818, 2222, 102 and 502, with Dropbear SSH on victim cellular modems over port 22. Actors downloaded project files, exfiltrated them over third-party hosted infrastructure, and at one victim uploaded a malicious project that preserved downstream ladder logic but overrode logic maintaining safe operating parameters, disabling shutdown and alarm logic; HMI/SCADA displays were also altered. Activity has been ongoing since at least March 2026, with operational disruption and financial loss at some victims in government services, water/wastewater and energy. In July 2026 CISA reported malicious activity against over 100 internet-exposed WWS systems, commonly PLCs connected directly to a cellular modem, in at least 12 states (Minnesota, Michigan, Georgia, South Dakota and New Jersey named in press), mostly small rural utilities. Press and third-party analysts suspect Iran (CyberAv3ngers named in Register coverage); the federal government had not formally attributed the July activity to a named group. No CVEs are the primary vector; Securin and the source article contain no malware names or hashes. Severity is analyst-assigned.

MITRE ATT&CK techniques by tactic:

Command and Control

T1219 Remote Access Tools

Impact

T1565 Data Manipulation

Remediation

Patches

  • Apply vendor firmware updates for Rockwell, Schneider Electric and Siemens PLCs; Rockwell MicroLogix/CompactLogix firmware affected by CVE-2017-16740 should be updated per Rockwell advisories

Immediate actions

  • Disconnect PLCs from the public internet; use a jump host, VPN or secure gateway and remove inbound port exposure (44818, 2222, 102, 502)
  • Inventory every cellular modem including contractor-installed ones; ensure none expose SSH (22) or management to the internet
  • Change default passwords and enable password protection on all controllers and modems
  • Block and review traffic from the AA26-097A IP indicators after vetting, and block hosting-provider IPs to PLC networks
  • Review running PLC project files for unauthorized changes (including AOIs) and verify offline backups before restoring

Workarounds

  • Place Rockwell physical mode switch in RUN; move to PROGRAM/REMOTE only for updates
  • Enable programming protection in Siemens TIA Portal where available
  • Disable Telnet, FTP, RDP, VNC and unused web services on OT devices

Longer-term hardening

  • Put MFA-enforcing gateways in front of each modem and controller pair
  • Use private APN, 5G PNI-NPN, cellular SD-WAN, ZTNA or site-to-site VPN for cellular OT connectivity
  • Allowlist source IPs so only known engineering workstations can reach OT assets remotely
  • Monitor asset and network traffic for logins, mode changes and program changes
  • Prioritize remediation by exploitation evidence and exposure rather than advisory volume alone; track exploited flaws absent from KEV

Affected and fixed versions

  • Rockwell Automation — Allen-Bradley CompactLogix, Micro850, MicroLogix 1400 PLCs
    Vulnerable versions: Internet-exposed units; firmware susceptible to CVE-2017-16740 (19 of 22 controllers in attacked cities per Forescout)
    Fixed in: Remove internet exposure; apply Rockwell-published firmware per advisory
  • Schneider Electric — Modicon M340 / BMX P34 PLCs
    Vulnerable versions: Internet-exposed units
    Fixed in: Remove internet exposure; follow Schneider CPCERT guidance
  • Siemens — SIMATIC S7-1200 series PLCs
    Vulnerable versions: Internet-exposed units
    Fixed in: Enable programming protection; follow Siemens ProductCERT guidance
  • Unitronics — Vision series PLCs with HMI
    Vulnerable versions: Units with default/missing passwords (at least 75 compromised Nov 2023-Jan 2024)
    Fixed in: Change default passwords; remove internet exposure
  • Various — Cellular modems/routers fronting PLCs (Dropbear SSH on port 22)
    Vulnerable versions: Exposed or weakly authenticated units
    Fixed in: Strong authentication, logging, private APN/VPN

Timeline

  • CISA alert on exploitation of Unitronics PLCs in water systems; at least 75 controllers compromised Nov 2023-Jan 2024 via default or missing passwords
  • Earliest AA26-097A historical IP associations (locked-ioc-14-171 range) with actor infrastructure begin in January 2025
  • Iranian-affiliated PLC activity against internet-facing Rockwell, Schneider and Siemens controllers ongoing since at least March 2026
  • FBI, CISA, NSA, EPA, DOE, CNMF and Treasury publish AA26-097A on Iranian-affiliated actors exploiting PLCs across US critical infrastructure
  • Malicious activity hits over 100 internet-exposed water and wastewater systems in at least 12 states, commonly PLCs connected directly to cellular modems
  • AA26-097A updated with new IP indicators (Table 1) covering September 2025 to July 2026 activity
  • Press reports Iran-linked CyberAv3ngers suspected in attacks on Minnesota water systems; Georgia and Michigan follow on 2026-08-03
  • Forescout reports 4,407 exposed Rockwell controllers (2,844 in US), ~70% of US devices on mobile carrier networks, 22 in cities hit by water attacks
  • CISA publicly states over 100 internet-exposed WWS systems were targeted in July, the first federal figure
  • Securin counts 791 Rockwell MicroLogix 1400 controllers exposed to the internet
  • The Register reports Securin Water Supply Chain Watch: 236 vendors, 20 exploited flaws not in CISA KEV, advisory data through 2026-11-20

Sources cited

Other reports on CVE-2017-16740

Further reading

Drafted by the Threadlinqs research pipeline from 12 sources; published ; last updated —.

Threadlinqs Intelligence — Real-Time Threat Detection Platform

// threat_feed
$ sort --newest
Showing all threats

Live intelligence console

Threat level

Latest Threats